Personal Homepage

Personal Information

MORE+

Associate professor

Supervisor of Master's Candidates

E-Mail:

Date of Employment:2022-01-03

School/Department:电气工程系

Administrative Position:学院外事联络员

Education Level:Postgraduate (Doctoral)

Business Address:逸夫楼603

Gender:Male

Degree:Doctoral degree

Status:Employed

Alma Mater:德国亚琛工业大学

Discipline:Power Electronics and Transmission

Zhiqing Yang

+

Gender:Male

Education Level:Postgraduate (Doctoral)

Alma Mater:德国亚琛工业大学

Paper Publications

Virtual Damping Control Design of Three-Phase Grid-Tied PV Inverters for Passivity Enhancement

Impact Factor:5.967
DOI number:10.1109/TPEL.2020.3035417
Journal:IEEE Transactions on Power Electronics
Place of Publication:United States
Key Words:Control design, grid-tied converter, passivity, resonances, stability
Abstract:The interconnection stability of a grid-tied inverter system can be investigated not only based on classical control theory, e.g., Nyquist criterion, but also from the energy dissipation point of view. If a critical resonance occurs within the regions, where the system equivalent impedance behaves passively, i.e., has only nonnegative real parts, the system stability can be guaranteed. Thus, it is preferred to design systems with passive regions over a wide-frequency range. This article investigates passivity properties influenced by different control loops and operating points in the dq frame, which facilitates the stability assessment in the frequency domain. Based on this, a virtual damping control method is proposed to improve the stability by enhancing the system passivity. By implementing a damping transfer function in the d - and q -axis individually, nonpassive regions can be accordingly reduced over a specific frequency range. Asymmetrical designs can be considered in the d - and q -axis according to corresponding passivity properties, which is impossible to be realized through symmetric physical filter components. The design procedure is elaborated based on a 2 MW inverter system, which is based on a combined graphical and analytical approach. Verifications are conducted based on a 1 kW prototype including both simulations and experimental results. The method applies to all types of grid-tied inverters with multiple control loops. This article is accompanied by a video demonstrating the validations.
Indexed by:Journal paper
Discipline:Engineering
Document Type:J
Volume:36
Issue:6
Page Number:6251-6264
ISSN No.:0885-8993
Translation or Not:no
Date of Publication:2020-11-03
Included Journals:SCI
Links to published journals:https://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63